Technical Specification Digital Pressure Switch ISE30-# Series ZSE30-# Series No.:PS##-OMF0010
Full View with DimensionsDimensions of Main Unit-9-PS##-OMF0010-BFull View with Dimensions
-10-Bracket suppliedPanel Mount TypeWith Front face protectivePS##-OMF0010-C
Panel Cut Dimensioms-11-PS##-OMF0010-C
-12-PS##-OMF0010-CNames and Function of Individual PartsOperation Indicator Lamp : Displays switch operation condition. (Green LCD) LCD Display
Install using the special bracket (Article No.ZS-27-B) or the panel mount adapter (Article No.ZS-27-C) available as options. Caution : Tighten
Notice when removing the switch Digital pressure switch with adapter for panel mounting can be removed from facility by making hook of the switch wide
Output Specification When the Lead wire with connector provided by SMC CORPORATION is used, the colors of wire (Brown, Black, Blue) will apply as show
Connector Connector Connecting/Disconnecting •When connecting the connector, insert it straight onto the pin holding the lever and connector body betw
SettingSetting Procedures Initialize Press the button continuously for more than two seconds. The display shown at the right will pop up to
4. Response Time Setting A response time for switch output can be set as user desires. Setting of a response time prevents chattering output. The res
-1-PS##-OMF0010-CContentsSafety Model Indication Method Specification Full View with Dimensions Names and Functions of Individual Parts Installat
If set to Manual Setting Press the button in the Measurement mode to display set values. “P_1” or “n_1” and the current set value will fl
If set to Auto Preset Mode Press the button during the Measurement mode to ready Auto Press mode and “AP1”will be displayed. Setting pressure
Peak And Bottom Hold Display Function Maximum and minimum values are always detected and updated during measurement. Displayed values can be held. In
PS##-OMF0010-C1. Display color Display Display character Meaning Sor When turning it on, it red displays it. SoG When turning it on, it green displa
PS##-OMF0010-C5.Manual set Display Display character Meaning mAn Manual set Hys Hysteresis mode (Display when operation mode is set) Wnd Window com
-2-The Digital Pressure Switch and this technical specification essential information for the protection of users and others from possible injury and
-3-PS##-OMF0010-COperator ♦This technical specification has been written for those who have knowledge of machinery and apparatus that use pneumatic eq
-4-PS##-OMF0010-CNOTE Follow the instruction given below when designing, selection and handling your pressure switch. ♦The instructions on design and
-5-•Blow off all the dust inside the pipes before piping the pressure switch. Otherwise it can cause damage or malfunction. •Clean the inside of the p
•Do not use a pressure switch nearby a place where electric surges are generated. Internal circuit elements of the pressure switch can deteriorate or
Model Indication Method For positive pressure : I S E 3 0 − − − For vacuum and low pressure : Z S E 3 0 − − −
ZSE30 ISE30 Rated Pressure Range -100 to 100 kPa 0 to 1 MPa Set Pressure Range -101 to 101 kPa -0.1 to 1 MPa Withstand Pressure 500 kPa 1.5 MPa